Conventional NDT Qualification (Multi skill – PT, MT, UTM)
Application Requirements
1. Looking for CV
2. Evidence of NDT experience
a) Have obtained a bachelor degree in engineering or science from a college or university, required 1 year of experience in the method for which being certified
b) Have satisfactorily completed two years of technical training in engineering or science at a university or college or technical school, required 2 years of experience in method for which being certified.
3. NDT Certification level II
a) Ultrasonic Thickness Measurement (UTM): Ultrasonic Testing (UT) Level II certification or Limited Certification of A-scan Thickness Measurement (UTMA)
b) Liquid Penetrant Testing (PT): Liquid Penetrant Testing (PT) Level II certification
c) Magnetic Particle Testing (MT): Magnetic Particle Testing (MT) Level II certification
4. Color blindness test report
5. Age not over 55 years
Preparing NDT equipment
1 Ultrasonic Thickness Measurement (UTM)
UTM instruments with data logger capable of A-Scan representation, probe, calibration blocks and couplant are required.
2 Liquid Penetrant Testing (PT)
Cleansing agent, liquid penetrant, developer and related hand tool are required.
3 Magnetic Particle Testing (MT)
The wet particle, aerosol spray white contrast paint, magnetic yoke and light meter are required.